Tæknilega Gögn
Hámarks stöðug rekstrarspenna | Uerv | 600VDC | 1000VDC | 1500VDC | 2000VDC |
Nafnrennsli straumur (T2) | In | 20ka | 20ka | 20ka | 20ka |
Hámarks dreifingarstraumur | IMAX | 40ka | 40ka | 40ka | 40ka |
Verndarstig | Up | 3.0kv | 3,5kV | 5,5kV | 6,5kV |
Leyfilegur skammhlaupsstraumur | ISCPV | 500A | |||
ICPV PV | 0,2 Ma | ||||
Tengingarstilling | samsíða | ||||
Viðbragðstími | tA | 25ns | |||
SPDSérstakur aftengingar | Mæli með | SSD40 | |||
Fjarskiptasamskipti | Með | ||||
Fjarskiptatenging | 1411: nei, 1112: NC | ||||
Fjarstarfsmannatölustraumur | 220v/0,5a |
Mechnical einkenni
Tenging ByScrew Terminals | 6-25mm |
Terminal skrúfa tog | 2,5nm |
Mælt með kapalþversnið | ≥10mm |
Settu vírlengd | 15mm |
Festing Din Rail | 35mm (EN60715) |
Verndun | IP20 |
Húsnæði | PBT/PA |
Logavarnarefni | Ul94vo |
OperationTemperature | -40 ℃ ~+70 ℃ |
Rekstur rakastigs | 5%-95% |
Vinnandi andrúmsloftsþrýstingur | 70kPa~106kpa |