Hafðu samband

BY1-12,5-PV

BY1-12,5-PV

Stutt lýsing:

Notkunarstaður: Strengjakassi, Inverter

Verndarmáti:(DC+)-PE,(DC-)-PE,(DC+)-(DC-)

Bylgjueinkunnir: Ialls=allt að 12,5 kA(10/350μs) Ialls=allt að 40 kA(8/20μs)

IEC/EN/UL Flokkur: Class I+II/Type 1+2/Type 1CA

Hlífðarþættir: Háorku MOV

Húsnæði: Stenganleg hönnun

 

Samræmi: IEC61643-31:2018EN 50539-11:2013+A1:2014UL1449 4. útgáfa


Upplýsingar um vöru

Vörumerki

BY1-12,5-PV 600 1000 1200 1500
IEC Rafmagns
Hámarks samfelld jafnstraumsspenna (DC+)-PE, (DC-)-PE UCPV 600V 1000V 1200V 1500V
(DC+)-(DC-) UCPV 600V 1000V 1200V 1500V
Nafnhleðslustraumur (8/20μs) In 20KA
Hvatflæðisstraumur (10/350μs) Iimp 6,25KA
Heildarlosunarstraumur (10/350μs) ISamtals 12,5KA
Heildarlosunarstraumur (8/20μs) ISamtals 40KA
Hámarks losunarstraumur (8/20μs) Ihámark 40KA
Spennuverndarstig (DC+)-PE. (DC-)-PE Up 2200V 4000V 4400V 5200V
(DC+)-(DC-) Up 2200V 4000V 4400V 5200V
Svartími tA <25ns
Skammhlaup núverandi einkunn ISCPV 2000A
Fjöldi hafna 1
UL rafmagns
Hámarks leyfð jafnspenna Vpvdc 600V 1000V 1200V 1500V
Spennuverndareinkunn (DC+)-PE. (DC-)-PE VPR 1600V 2500V 3000V 4000V
(DC+)-(DC-) VPR 1600V 2500V 3000V 4000V
Nafnhleðslustraumur (8/20μs) In 25KA
Skammhlaup núverandi einkunn SCCR 35KA 50KA 55KA 65KA

  • Fyrri:
  • Næst:

  • Skrifaðu skilaboðin þín hér og sendu okkur