Hafðu samband

BY1-12,5 1P+1 3P+1

BY1-12,5 1P+1 3P+1

Stutt lýsing:

Notkunarstaður: Aðaldreifingarstöðvar

Netkerfi: TT,TN-S

Verndarmáti: LN,N-PE

Bylgjueinkunnir: Iimp=12,5kA(10/350μs) In=20kA(8/20μs)

IEC/EN/UL Flokkur: Class I+II /Type 1+2/Type 1CA

Hlífðarþættir: High Energy MOV og GDT

Hús: Stengjanleg hönnun

Samræmi: IEC61643-11:2011 EN61643-11:2012 UL 1449 4. útgáfa


Upplýsingar um vöru

Vörumerki

BY1-12,5/1P+1 75 150 275 320
IEC Rafmagns
Nafnspenna (50/60Hz) 60v 120v 230v 230v
Hámarks samfelld rekstrarspenna (LN) Uc 75V 150v 275v 320v
(N-PE) Uc 255V 255v 255v 255v
Nafnhleðslustraumur (8/20μs) (LN)/(N-PE) In 20KA/25KA
Hámarks losunarstraumur (8/20μs) (LN)(N-PE) lhámark 50KA/50KA
Hvatflæðisstraumur (10/350μs) (LN)/(N-PE) limp 12,5KA/25KA
Sérstök orka (LN)/(N-PE) W/R 39KJ/Ω /156KJ/Ω
Hleðsla (LN)/(N-PE) Q 6.25As/12.5As
Spennuverndarstig (LN)/(N-PE) Up 700v/1500v 1000v/1500v 1500v/1500v 1600v/1500v
Fylgdu núverandi truflunareinkunn (N-PE) Ifi 100 ARMS
Svartími (LN)/(N-PE) tA <25ns/<100ns
Varaöryggi (hámark) 315A/250AgG
Skammhlaupsstraumeinkunn (AC) (LN) ISCCR 25KA/50KA
TOV Standast 5s (LN) UT 114V 180V 335V 335V
TOV 120 mín (LN) UT 114V 230V 440V 440V
Mode Standast Örugg mistök Örugg mistök Örugg mistök
TOV þola 200ms (N-PE)  UT 1200v
Fjöldi hafna 1
UL rafmagns
Hámarks samfelld rekstrarspenna (AC) (LN)/(N-PE) MCOV 75v/255v 150v/255v 275v/255v 320v/255v
Spennuverndareinkunn (LN)/(N-PE) VPR 330v/1200v 600v/1200v 900v/1200v 1200v/1200v
Nafnhleðslustraumur (8/20μs) (LN)/-PE) In 20kA/20KA 20kA/20KA 20kA/20KA 20kA/20KA
Skammhlaupsstraumeinkunn (AC) (LN) SCCR 100KA 200KA 150KA 150KA

  • Fyrri:
  • Næst:

  • Skrifaðu skilaboðin þín hér og sendu okkur